Victron Energy Battery Protect 12/24V-65A

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which
would damage the battery) or before it has insufficient power left to crank the engine.

12/24V auto ranging
The BatteryProtect automatically detects system voltage

Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages.
The seven segment display will indicate which setting has been chosen.

A special setting for Li-ion batteries
In this mode the Battery Protect can be controlled by the VE.Bus BMS.
Note: the Battery Protect can also be used as a charge interrupter in between a battery charger and a Li-ion
battery. See connection diagram in the manual.

Ultra low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown.
Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage
exceeds 16V respectively 32V.

Ignition proof
No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12
seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open
collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a
buzzer, LED or relay.

Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again
to the connect threshold within this time period (after the engine has been started for example), the load will not
be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset
reconnect voltage.

 

Victron Energy Battery Protect 12/24V-65A Specifications

Max continuous load current – 65A
Peak current – 300A
Operating voltage range – 6 to 35V
Current consumption – 0.6 to 1.5 mA
Alarm output delay – 12 seconds
Max load on alarm output – 50 mA (short circuit proof)
Load disconnect delay – 90 seconds
Load reconnect delay – 30 seconds
Operating temperature – ( – 40 to + 40C)
Humidity – 95% max

Victron Energy Battery Protect 12/24V-65A Enclosure

Colour – Blue RAL 5012
Connection – M6 bolts
Weight – 0.20 kg
Dimensions ( h * w * d ) – 40 * 48 * 106 mm

Victron Energy Battery Protect 12/24V-65A Standards

Safety – EN 60950
Emission – EN 61000-6-3, EN 55014-1
Immunity – EN 61000-6-2, EN 61000-6-1, EN 55014-2
Automotive Directive – EN 50498