Victron LiFePO4:


Lithium-iron-phosphate (LiFePO4 or LFP) is the safest of the mainstream li-ion battery types. The nominal voltage of a LFP cell is 3,2V (lead-acid: 2V/cell). A 12,8V LFP battery therefore consists of 4 cells connected in series; and a 25,6V battery consists of 8 cells connected in series.


Rugged


A lead-acid battery will fail prematurely due to sulfation:


If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all, fully charged).


If it is left partially charged or worse, fully discharged (yacht or mobile home during wintertime).


A LFP battery does not need to be fully charged. Service life even slightly improves in case of partial charge instead of a full charge. This is a major advantage of LFP compared to lead-acid. Other advantages are the wide operating temperature range, excellent cycling performance, low internal resistance and high efficiency (see below). LFP is therefore the chemistry of choice for very demanding applications.


Efficient


In several applications (especially off-grid solar and/or wind), energy efficiency can be of crucial importance. The round trip energy efficiency (discharge from 100% to 0% and back to 100% charged) of the average lead- acid battery is 80%. The round trip energy efficiency of a LFP battery is 92%. The charge process of lead-acid batteries becomes particularly inefficient when the 80% state of charge has   been reached, resulting in efficiencies of 50% or even less in solar systems where several days of reserve energy is required (battery operating in 70% to 100% charged state). In contrast, a LFP battery will still achieve 90% efficiency under shallow discharge conditions.


Size and weight


Saves up to 70% in space.


Saves up to 70% in weight


Expensive?


LFP batteries are expensive when compared to lead-acid. But in demanding applications, the high initial cost will be more than compensated by longer service life, superior reliability and excellent efficiency.


Bluetooth


With Bluetooth cell voltages, temperature and alarm status can be monitored. Very useful to localize a (potential) problem, such as cell imbalance.


Our LFP batteries have integrated cell balancing and cell monitoring.


Up to 5 batteries can be paralleled and up to four batteries can be series connected, so that a 48V battery bank of up to 1500Ah can be assembled. The cell balancing/monitoring cables can be daisy- chained and must be connected to a Battery Management System (BMS).


Battery Management System (BMS) The BMS will:


1.Disconnect or shut down the load whenever the voltage of a battery cell decreases to less than 2,5V.


2.Stop the charging process whenever the voltage of a battery cell increases to more than 4,2V.


3.Shut down the system whenever the temperature of a cell exceeds 50°C. See the BMS datasheets for more features


*Images for display purposes only. New 160AH model has superseded 150AH.


 

Battery specification

 

VOLTAGE AND CAPACITY

LFP-

Smart 12,8/60

LFP-

Smart 12,8/90

LFP-

Smart 12,8/100-a

LFP-

Smart 12,8/150

LFP-

Smart 12,8/160-a

LFP-

Smart 12,8/200

LFP-

Smart 12,8/300

LFP-

Smart 25,6/200

Nominal voltage

12,8V

12,8V

12,8V

12,8V

12,8V

12,8V

12,8V

25,6V

Nominal capacity @ 25°C*

60Ah

90Ah

100Ah

150Ah

160Ah

200Ah

300Ah

200Ah

Nominal capacity @ 0°C*

48Ah

72Ah

80Ah

125Ah

130Ah

160Ah

240Ah

160Ah

Nominal capacity @ -20°C*

30Ah

45Ah

50Ah

75Ah

80Ah

100Ah

150Ah

100Ah

Nominal energy @ 25°C*

768Wh

1152Wh

1280Wh

1920Wh

2048Wh

2560Wh

3840Wh

5120Wh

*Discharge current ≤1C

 

CYCLE LIFE (capacity ≥ 80% of nominal)        

80% DoD

2500 cycles

70% DoD

3000 cycles

50% DoD

5000 cycles

DISCHARGE

Maximum continuous discharge current

120A

180A

200A

320A

320A

400A

600A

400A

Recommended continuous

discharge current

≤60A

≤90A

≤100A

≤160A

≤160A

≤200A

≤300A

≤200A

End of discharge voltage

11.2V

11.2V

11.2V

11.2V

11.2V

11.2V

11.2V

22.4V

OPERATING CONDITIONS

Operating temperature

Discharge: -20°C to +50°C

Charge: +5°C to +50°C

Storage temperature

-45°C to +70°C

Humidity (non-condensing)

Max. 95%

Protection class

IP 22

CHARGE

Charge voltage

Between 14V/28V and 14,4V/28,8V (14,2V/28,4V recommended)

Float voltage

13,5V/27V

Maximum charge current

120A

180A

200A

300A

320A

400A

600A

400A

Recommended charge current

≤30A

≤45A

≤50A

≤75A

≤80A

≤100A

≤150A

≤100A

OTHER

Max storage time @ 25°C*

1 year

BMS connection

Male + female cable with M8 circular connector, length 50cm

Power connection (threaded inserts)

M8

M8

M8

M8

M10

M10

M10

M8

Dimensions (hxwxd)mm

240x285x132

249x285x168

197x321x152

237x321x152

237x321x152

297x425x274

347x425x274

317x631x208

Weight

12kg

16kg

15kg

20kg

20kg

42kg

51kg

56Kg

*When fully charged