LITHIUM SUPERPACK 25.6V 50AH

LITHIUM SUPERPACK 25.6V 50AH

VICTRON SUPERPACK LITHIUM IRON PHOSPHATE (LIFEP04) BATTERY • BUILT IN BMS


Brand: Victron

Reference No. BAT524050705

0

1,899.00Incl

1,726.36Excl
1899.0AUD
Add to Cart

Victron lithium superpack:


Integrated BMS and safety switch:

The SuperPack batteries are extremely easy to install, not needing any additional components. The internal switch will disconnect the battery in case of over discharge, over charge or high temperature.


Abuse proof:

A lead-acid battery will fail prematurely due to sulfation:

    •If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all, fully charged).

   •If it is left partially charged or worse, fully discharged.

A Lithium-Ion battery does not need to be fully charged. Service life even slightly improves in case of partial charge instead of a full charge. This is a major advantage of Li-ion compared to lead-acid.


Efficient:

In several applications (especially off-grid solar), energy efficiency can be of crucial importance. The round-trip energy efficiency (discharge from 100% to 0% and back to 100% charged) of the average lead-acid battery is 80%. The round-trip energy efficiency of a Li-ion battery is 92%. The charge process of lead-acid batteries becomes particularly inefficient when the 80% state of charge has been reached, resulting in efficiencies of 50% or even less in solar systems where several days of reserve energy are required (battery operating in 70% to 100% charged state). In contrast, a Li-ion battery will still achieve 90% efficiency even under shallow discharge conditions.


Can be connected in parallel:

The batteries can be connected in parallel. Series connection is not allowed. Use in upright position only.

Lithium SuperPack

 

 

LSP 25,6/50

Chemistry

LiFePO4

Nominal voltage

25,6V

Nominal capacity @ 25°C

 


50Ah

Nominal capacity @ 0°C

 

 

40Ah

Nominal energy @ 25°C

 

 

1280Wh

Cycle life @ 80% DoD and 25°C

2500 cycles

CHARGE and DISCHARGE

Max. cont. discharge current

 

 

50A

Peak discharge current (10 sec)

 

 

100A

End of discharge voltage

20V

Charge voltage, absorption**

28.4V – 28.8V

Charge voltage, float

27V

Max. cont. charge current

 

 

50A

OPERATING CONDITIONS

Parallel configuration

Yes, unlimited

Series configuration

No

Operating temperature

Discharge: -10°C to +50°C Charge: +5°C to +45°C

Storage temperature

-40°C to +65°C

Max. storage time when fully

charged

1 year25°C3 months ≤40°C

Humidity

(non-condensing)

Max. 95%

Protection class

IP 43

OTHER

Power connection (threaded inserts)

 

 

M8

Dimensions (LxWxH) mm

 

 

395 x 110 x 286

Weight

 

 

16kg

**The absorption period should preferably not exceed 4 hrs. A longer absorption period may slightly reduce service life.

Victron 24V 50AH SuperPack spec sheet-