REPLACEMENT TEMP SENSOR EPOWER CHARGER

REPLACEMENT TEMP SENSOR EPOWER CHARGER


Brand: Enerdrive

Reference No. EN3TEMP

0

44.00Incl

40.00Excl
44.0AUD
Add to Cart

Replacement Temperature Sensor to Suit ePOWER Chargers.

Model

EN31220

EN31240

EN31260

EN32430

CHARGER OUTPUT

Output Current (Maximum)

20A

40A

60A

30A

OUTPUT VOLTAGE RANGE

Charge

14.2 – 15.5 V

28.4 – 31.0V

Float

13.4 – 13.8 V

26.8 – 27.6V

– Equalize

16.0 V

32.0V

Charging Control

Four stages (Bulk/Absorption/Float/Maintenance)

Two stages (Bulk/Absorption)

Constant Power Supply (Program setting)

Priority Battery Bank Charging

DC Output Bank

Three (1 fully independent, 2 common with diode isolation)

Selectable Battery Type

Gel, AGM, Flooded, Lithium, Program

Standby Current

< 2 mA

CHARGER INPUT

AC Input Voltage (Nominal)

90 to 265 VAC

AC Input Operating Range

207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max)

207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max)

207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)

207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)

AC Input Frequency Range

47 – 63 Hz

Power Consumption

350W (Full Load)

700W (Full Load)

1050W (Full Load)

1050W (Full Load)

Power Factor Correction

Yes

Charger Efficiency

> 82%

PROTECTION AND FEATURES

Reverse Polarity

Yes, (with user replaceable fuse/s)

Over Charge

Yes, unit shutdown

Over Temperature

Yes, unit de-rated and shutdown

Output Short Circuit

Yes, (with user replaceable fuse/s)

Cooling

Forced air ventilation (thermo controlled fan)

Temperature Setting

Hot, Normal, Cold (no sensor connected)

Battery Temp Sensor Port

RJ12 (standard battery temp. sensor supplied)

DISPLAY

LCD Display (with back light)

Charging status, Battery Voltage, Output Current & Fault Codes.

AC INPUT AND DC OUTPUT CONNECTION

AC Input Connection

IEC with Supplied 1.2M Power Lead

DC Output Connection

Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread

DC Output Ground

Single Heavy Duty Common Ground Stud

ENVIRONMENTAL AND OPERATING TEMPERATURE

Storage Range

-40° to 70° C

Operating Range

-20° to 60° C

Humidity

5-95%, relative humidity non-condensing

Ingress Protection

IP32 (Basic drip proof in vertical orientation)

Base Unit Weight and Dimensions

Weight: (kg)

2.4

2.6

4.0

4.0

Dimension: (mm) L x W x H

295 x 206 x 86

295 x 206 x 86

356 x 206 x 99

356 x 206 x 99

Optional Accessories

Remote Digital Display / Enerdrive Part Number EN3REM

Regulatory Compliance

Complies with AS/NZS 60335.2.29 Including Australian deviations.