SKYLLA-IP44 12/60 (3)

SKYLLA-IP44 12/60 (3)

VICTRON SKYLLA BATTERY CHARGER • 12V 60A 3 OUTPUT 120-240V


Brand: Victron

Reference No. SKY012060100

0

1,156.05Incl

1,050.95Excl
1156.05AUD
Add to Cart

Skylla-IP44 (1+1): two outputs to charge 2 battery banks


The Skylla-IP44 (1+1) features 2 isolated outputs. The second output, limited to approximately 3A and with a slightly lower output voltage, is intended to top up a starter battery.


Skylla-IP44 (3): three full current outputs to charge 3 battery banks


The Skylla-IP44 (3) features 3 isolated outputs. All outputs can supply the full rated output current.


IP44 protection


Steel epoxy powder coated case and splash proof. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.


LCD display


For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use.


CAN bus interface (NMEA2000)


To connect to a CAN bus network, to a Skylla-i Control panel or to the Color Control digital display.


Synchronised parallel operation


Several chargers can be connected in parallel and synchronised with help of the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables.


The right amount of charge for a lead-acid battery: variable absorption time


When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.


Preventing damage due to  excessive gassing:  the BatterySafe mode


If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP44 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.


Less maintenance and aging when the battery is not in use: the Storage mode


The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.


To increase battery life: temperature compensation


Every Skylla-IP44 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.


Battery voltage sense


In order to compensate for voltage loss due to cable resistance, the Skylla-IP44 is provided with a voltage sense facility so that the battery always receives the correct charge voltage.


Use as a power supply


As a result of the excellent control circuit, the Skylla-IP44 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available.


Li-Ion (LiFePO4) ready


Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN bus port.


Learn more about batteries and battery charging


To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free of charge from Victron Energy and downloadable from www.victronenergy.com).

 

Skylla-IP44

12/60 (1+1)

12/60 (3)

24/30 (1+1)

24/30 (3)

Input voltage (VAC)

120/230 V

Input voltage range (VAC)

90-265 V

Maximum AC input current @ 100 VAC

10 A

Frequency)

45-65 Hz

Power factor

0,98

Charge voltage 'absorption' (1)

14,4 V

28,8 V

Charge voltage 'float'

13,8 V

27,6 V

Charge voltage ‘storage’

13,2 V

26,4 V

Charge current (2)

60 A

3 x 60A

(max total output: 60 A)

30 A

3 x 30 A

(max total output: 30 A)

Charge current starter batt. (A)

3 A

n. a.

3 A

n. a.

Charge algorithm

7 stage adaptive

Battery capacity

300-600 Ah

150-300 Ah

Charge algorithm, Li-Ion

3 stage, with on-off control or CAN bus control

Temperature sensor

Yes

Can be used as power supply

Yes

Remote on-off port

Yes (can be connected to a Li-Ion BMS)

CAN bus communication port (VE.Can)

Two RJ45 connectors, NMEA2000 protocol, not isolated

Synchronised parallel operation

Yes, with VE.Can

Alarm relay

DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC

Forced cooling

Yes (internal air circulation)

Protection

Battery reversepolarity(fuse)                           Outputshortcircuit                           Overtemperature

Operating temp. range

-20 to 60°C (Full output current up to 40°C)

Humidity (non-condensing)

max 95%

ENCLOSURE

Material & Colour

steel (blue RAL 5012)

Battery-connection

M6 bolts

230 VAC-connection

screw-clamp 6mm² (AWG 10)

Protection category

IP44

Weight

6kg   (14 lbs)

Dimensions (hxwxd)

401 x 375 x 265 mm

16 x 15 x 10.5 inch

STANDARDS

Safety

EN 60335-1, EN 60335-2-29

Emission

EN 55014-1, EN 61000-6-3, EN 61000-3-2

Immunity

EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3

1) Output voltage range10-16Vresp.       2) Up to 40°C (100°F)ambient.

20-32V.              Output will reduce to 80% at 50°C, and to 60% at60°C.

 

Spec Sheet-


Manual-


Dimensions-