Enerdrive Elite Lifepo4 12V 100Ah Dc40 & Ac40
ENERDRIVE EPL-100-12V-ELITE 12V 100AH LITHIUM IRON PHOSPHATE (LIFEPO4) BATTERY • EN3DC40+ EPOWER DC-DC CHARGER • EN31240 EPOWER 240V 40A AC CHARGER • 5 YEAR WARRANTY
Brand: Enerdrive
Reference No. K-100L-DC40-AC40
**BUNDLE CONSISTS OF ENERDRIVE EPL-100-12V-ELITE 12V 100AH LITHIUM BATTERY, EN3DC40+ EPOWER DC-DC CHARGER & EN31240 AC CHARGER**
Enerdrive 12V 100AH eLITE lithium battery:
The new Enerdrive 12v 100Ah eLITE Lithium Battery has been designed as an “entry level” lithium battery for the customer who wants to get into the lithium market without having to spend big. This unit is a stripped back version of the ever popular 100Ah B-TEC Lithium battery but, without all the bells and whistles.
Wireless Battery Monitoring Technology, not in this little beauty. To save costs, we decided to remove the monitoring option from the eLITE. Does this reduce the quality of the battery?, certainly not. Its all about offering a high quality battery at an entry level price.
Battery management system:
The battery is also equipped with an internal Battery Management System that can monitor and optimise each Prismatic cell within the battery during normal operation. It will protect the battery pack from over charge, over discharge, over temperature & short circuit. The BMS helps to ensure safe and accurate operation of the battery.
Size & weight savings:
Lithium v AGM Capacities;
100Ah Lithium = 160Ah AGM
125Ah Lithium = 200Ah AGM
200Ah Lithium = 320Ah AGM
300Ah Lithium = 480Ah AGM
(Based on standard depth of discharge for both Lithium (80%) and AGM (50%).
The Enerdrive eLITE battery provides 60% more usable power than its equivalent lead acid cousin and being nearly 50% lighter and 30% smaller makes for a superior alternative. The Enerdrive eLITE battery is perfect for camper trailers, 4WD’s (AUX battery), caravans, small water craft, low power communication sites or any other application that requires the use of a single deep cycle battery that meets the amp hour capacity.
About Enerdrive:
With over 7 years of researching, designing and testing lithium batteries and the associated charging systems, Enerdrive are at the forefront of lithium battery systems in Australia. Enerdrive are the only Australian company that can supply a fully integrated self-branded energy system to suit your setup. With over 3000 complete systems in operation Australia wide, Enerdrive is regarded as the leader in the field of lithium batteries and energy systems for Mobile, Marine and Remote applications.
Please Note:
The eLITE battery is capable to be paralleled to a second eLITE battery of the same size. For maximum performance and lifespan of your eLITE battery, no more than 2 batteries should be connected together to increase your overall capacity. Overall loads when paralleled should not exceed the current limits of a single batteries BMS. The 100Ah battery is able to accept a maximum inverter capacity of 1000W only. Exceeding the maximum inverter capacity can damage the BMS Management within the battery.
If you are requiring a battery system larger than eLITE, please look at the ePOWER B-TEC battery range or the Enerdrive Pro Series Power Pack Systems of which can offer multiple parallel and series connections with Active Cell Balancing Protection across the entire pack.
Enerdrive ePOWER DC2DC+ Battery Charger 40A:
The Enerdrive ePOWER DC2DC+ Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller. With two inputs available, the main/house battery will be charged from either the engine while underway, or via the solar panels when stationary. The process to choose either engine or solar is fully automatic and both functions are controlled from within the unit itself without the need for external relays. During normal operation the ePOWER DC2DC+ Battery Charger will do a full charge cycle to float stage on the house battery bank with ability to choose either GEL, AGM, Flooded, Custom Programmable or Lithium. Once float stage is reached the charger transitions to a power supply mode to support any on-board DC loads.
Multistage charging process:
The ePOWER DC2DC+ Battery Charger is a fully automatic, set and forget charger. It is designed to quickly and accurately recharge your deep cycle batteries utilising charger algorithms that help to maximise the life of your specialised deep cycle batteries. The ePOWER DC2DC+ Battery Charger features multistage smart charging technology that enables the charger to be connected to your battery bank permanently. With the input of multiple sources, you can be assured of charging your batteries whenever underway; or when the sun is shining on your solar array. As dictated by battery manufacturer’s recommendations, deep cycle batteries require a multistage charge sequence for perfect, fast and accurate charging. The Enerdrive ePOWER DC2DC+ smart charger delivers three primary charge stages.
Stage 1:
– Bulk or Boost charge; The battery is charged at full rated output current of the charger until the battery reaches its final charging voltage, known as its absorption voltage. In this step, around 80% of the battery is recovered as fast as possible.
Stage 2:
– Absorption Charge; With the charger voltage held steady, the remaining 20% is replaced with the charger allowing the current to taper off as the battery approaches full charge.
Stage 3:
– Float; Finally, in the float stage the charger voltage is lowered and held at a constant and safe predetermined level. This prevents the battery from being overcharged, yet allows the charger to supply enough current to make up for the self-discharge losses of the battery, while supporting any additional loads connected to the battery (such as DC lighting and refrigerators). This stage allows for the charger to be used as a DC power supply.
Smart Charging Feature:
The ePOWER DC2DC+ Battery Charger will regulate its output based on the loads connected to your battery bank. This function is important to maintain the life of your battery bank as some battery chargers mistake loads for discharge and continue to keep the batteries in the bulk or absorption stage for extended periods of time, which will damage the battery bank. The ePOWER DC2DC+ Battery Charger has two methods of load based regulation to ensure your battery charger transitions to float when it should do so.
Features:
- Two totally independent DC Inputs for both engine and solar regulation charging one house battery bank output
- DC M6 screw terminals that will allow for large battery cable connection between all sources
- A dedicated Maximum Power Point (MPPT) solar regulator
- The same battery algorithms as included in our AC mains ePOWER battery charger. GEL, AGM, Flooded, Lithium and the ability to create a full custom profile
- Vehicle input allows for either 12 or 24v and a maximum solar input of 45V/800W
- 40A output up to 40+°C with thermo controlled fan cooling
- Fully programmable LCD display to show which source is charging the battery along with charger status, voltage and amperage
- Temperature sensor included in charger for more accurate battery charging
Enerdrive EN31240 AC charger:
The Enerdrive ePOWER 40A Battery Charger is a fully automatic, “set and forget” charger. It is designed to quickly and accurately recharge your batteries using algorithms that help maximise service life. Multistage smart charging technology enables the charger to be connected to your battery banks permanently. As dictated by battery manufacturer’s recommendations, batteries require a multistage charge sequence for perfect, fast and accurate charging. Our ePOWER multistage smart 40A battery charger deliver four primary charge stages:-
Stage 1:
Bulk or Boost Charge; The battery is charged at full rated output current of the charger until the battery reaches its final charging voltage, known as its absorption voltage. In this step, around 80% of the battery capacity is recovered as fast as possible.
Stage 2:
Absorption Charge; With the charger voltage held steady the remaining 20% is replaced allowing the current to drop as the battery approaches its full charge.
Stage 3:
Float; Finally, in the float stage the charger voltage is lowered and held at a constant and safe predetermined level. This prevents the battery from being overcharged while supporting any additional loads connected to the battery, such as DC lighting and refrigerators. This stage allows for the charger to be used as a DC power supply. Stage 4 – Maintenance; This stage is a regular timed “return to bulk” stage. After 7 days of constant operation in “float” the Enerdrive ePOWER Battery Charger will switch the charger from float to bulk to agitate the batteries electrolyte helping to provide an extended service life.
Bank 1 PRIORITY – Charge Where You Need it Most:
The ePOWER 40A Battery Charger delivers a priority charge to Bank 1, or your main house battery bank which allows the charger to get this bank recharged the quickest, then transition the cycle to the lesser bank 2 & 3 batteries. Enerdrive Battery Charger Bank One Priority The priority function also allows you to have a battery chemistry different to the other two, such as an AGM battery for house and lead calcium for your start banks. In the event that all 3 banks are in need of a charge, an over-ride function helps recover all 3 banks quickly and evenly before switching back to prioritise on Bank 1.
It’s All About Lithium:
The recent advances in high capacity Lithium battery technology have seen the need to develop a battery charger suited to their needs. With most traditional ‘smart’ chargers their suitability to Lithium batteries is limited. Lithium batteries require a constant current / constant voltage charge algorithm and are unique in that almost every amp-hour of charge delivered by the charger is accepted as one amp hour into the battery, hence the need to deliver a constant current as long as possible. The Enerdrive ePOWER charger can be programmed for Lithium batteries. This setting delivers the full rated output of the charger constantly with the charger switching to power supply mode once the voltage peak is met (indicating a full battery bank). The graph below shows the ePOWER charger algorithm perfectly supporting Lithium battery requirements. Enerdrive Battery Charger Lithium Features ePOWER Battery Charger Display
The Display Panel:
The ePOWER 40A Battery Charger display gives you all the information you need for the operation of your charger. At a glance, key information such as charger amps, battery voltage and charge state continually alternate on the screen.When in float / power supply mode, the load amps are displayed so you can see exactly what the charger is doing. The display also allows you to program all settings of the charger, as well as activate the silent mode. Silence when you need it – By pressing the “SEL” button for 5 seconds, the ePOWER Charger enters the ‘Silent’ mode that prohibits the fan from working. This ensures totally silent and safe operation at night, ideal if the charger is located close to your sleeping quarters. Silent mode limits current output to no more than 50%, and is programmed to remain on for 12 hours before automatically returning to a normal ‘fan-on & full output’ setting.
40A Battery Charger Features:
Multistage Charging- Fully automatic multistage 40A battery charger with the ability to charge 3 separate battery banks.
Separate Battery Banks- Isolated charging design where battery bank one is separate from battery bank two and three.
Programmable- Battery bank 1 can be programmed with a different charge algorithm over banks 2 and 3.
Current Control- User adjustable current output (e.g. Dial the 40amp unit back to run off a 1kVA generator).
Smart Charging- The ePOWER 40A battery charger will regulate its output based on the loads connected to your battery banks.
Wide AC Input Range- Operates on both 110V / 60Hz and 240V / 50Hz.
LED Display- Easy to use “set and select” menu along with scrolling charger status.
Silent Mode- Disables the cooling fan for total silent operation at night or whenever required. Activation reduces charge output by half and locks out fan for 12 hours.
Temperature Sensor- Battery temperature sensor included with 3 meter cable.
Warranty- 5 Year Warranty from an Australian company renowned for customer support.
EPL-100-12V-ELITE-
Normal Specification | EPL-100-12V-ELITE |
|
|
Nominal Voltage | 12.8V | ||
Nominal Capacity | 100Ah |
|
|
Cycle Life (DOD – 80% under controlled conditions) | ≥ 2000 Cycles | ||
Standard Charge Specification (Lithium profile charger required) | |||
Battery Charge Temperature | 0 ̴ 45°C | ||
Normal Charge Voltage CV/CC* | 14.20 ̴ 14.60V | ||
Standby (Float) Voltage | 13.50 ̴ 13.60V | ||
Maximum Charge Current | 80A @ 25°C for 30mins |
|
|
Recommended Charge Current for Maximum Life | ≤33A |
|
|
Standard Discharge Specification | |||
Battery Discharge Temperature | -20 ̴ 60°C | ||
Battery Output Voltage Range | 11.00 ̴ 14.60V | ||
Maximum Discharge Current | 100A @ 25°C ± 5°C for 30mins |
| |
Pulse Discharge Current | 450A for 1.0s | ||
Discharge Cut-off Voltage | ≤11.20V | ||
Circuit Protection | |||
The battery is supplied with a LiFePO4 Battery Management System BMS that can monitor and optimize each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery. | |||
Over-Charge Protection | |||
Over-charge Protection Per Cell | 3.90V ± 0.03V | ||
Over-charge Release Per Cell | 3.60V ± 0.05V | ||
Over-charge Release Method | Discharge below release voltage | ||
Over-Discharge Protection | |||
Over-discharge Protection Per Cell | 2.80V ± 0.05V | ||
Over-discharge Release Per Cell | 3.20V ± 0.05V | ||
Over-discharge Release Method | Apply Charge/Voltage ≥12.8V | ||
Over Current Protection | |||
Discharge Over Current | 110A for 30s – 450A for 1s |
| |
Protection Reset Time | 5s Auto Release | ||
Over Current Release Method | Disconnect Load | ||
Over Temperature Protection | |||
Battery Discharge Over Temperature | Protection to 65°C ± 5°C | ||
Release at 50°C ± 5°C | |||
Battery Charge Over Temperature | Protection to 55°C ± 5°C | ||
Release at 45°C ± 5°C | |||
Short Circuit Protection | Auto release after 5s | ||
Mechanical Characteristics | |||
Dimensions | Length 310mm |
| |
Width 170mm |
| ||
Height 225mm |
| ||
Weight | Approx 12Kg |
|
|
Storage Information | |||
Temperature & Humidity Range | ≤ 30 days -20°C ̴ 35°C, 45 ̴ 75% RH | ||
≥ 30 days -10°C ̴ 30°C, 45 ̴ 75% RH | |||
Self-discharge Rate | ≤ 3% Per Month |
EN31240-
Model | EN31220 | EN31240 | EN31260 | EN32430 |
CHARGER OUTPUT | ||||
Output Current (Maximum) | 20A | 40A | 60A | 30A |
OUTPUT VOLTAGE RANGE | ||||
Charge | 14.2 – 15.5 V | 28.4 – 31.0V | ||
Float | 13.4 – 13.8 V | 26.8 – 27.6V | ||
– Equalize | 16.0 V | 32.0V | ||
Charging Control | Four stages (Bulk/Absorption/Float/Maintenance) | |||
Two stages (Bulk/Absorption) | ||||
Constant Power Supply (Program setting) | ||||
Priority Battery Bank Charging | ||||
DC Output Bank | Three (1 fully independent, 2 common with diode isolation) | |||
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program | |||
Standby Current | < 2 mA | |||
CHARGER INPUT | ||||
AC Input Voltage (Nominal) | 90 to 265 VAC | |||
AC Input Operating Range | 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) | 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
AC Input Frequency Range | 47 – 63 Hz | |||
Power Consumption | 350W (Full Load) | 700W (Full Load) | 1050W (Full Load) | 1050W (Full Load) |
Power Factor Correction | Yes | |||
Charger Efficiency | > 82% | |||
PROTECTION AND FEATURES | ||||
Reverse Polarity | Yes, (with user replaceable fuse/s) | |||
Over Charge | Yes, unit shutdown | |||
Over Temperature | Yes, unit de-rated and shutdown | |||
Output Short Circuit | Yes, (with user replaceable fuse/s) | |||
Cooling | Forced air ventilation (thermo controlled fan) | |||
Temperature Setting | Hot, Normal, Cold (no sensor connected) | |||
Battery Temp Sensor Port | RJ12 (standard battery temp. sensor supplied) | |||
DISPLAY | ||||
LCD Display (with back light) | Charging status, Battery Voltage, Output Current & Fault Codes. | |||
AC INPUT AND DC OUTPUT CONNECTION | ||||
AC Input Connection | IEC with Supplied 1.2M Power Lead | |||
DC Output Connection | Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread | |||
DC Output Ground | Single Heavy Duty Common Ground Stud | |||
ENVIRONMENTAL AND OPERATING TEMPERATURE | ||||
Storage Range | -40° to 70° C | |||
Operating Range | -20° to 60° C | |||
Humidity | 5-95%, relative humidity non-condensing | |||
Ingress Protection | IP32 (Basic drip proof in vertical orientation) | |||
Base Unit Weight and Dimensions | ||||
Weight: (kg) | 2.4 | 2.6 | 4.0 | 4.0 |
Dimension: (mm) L x W x H | 295 x 206 x 86 | 295 x 206 x 86 | 356 x 206 x 99 | 356 x 206 x 99 |
Optional Accessories | Remote Digital Display / Enerdrive Part Number EN3REM | |||
Regulatory Compliance | Complies with AS/NZS 60335.2.29 Including Australian deviations. |
EN3DC40+
Model | EN3DC40+ |
Ouput Rating | |
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A – 50A |
Output power | 775W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when in use | = < 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
Input Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤23 input, 500W (600W allowable) ≥37.5-45V input, 750W (800W allowable) |
Input Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32DC |
Dimensions | |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |