Enerdrive PWM 12V solar controller:
For maintenance free protection of your batteries and solar panels the controllers regulated output will prevent batteries overcharging. Load Disconnect (LD) feature will protect batteries from being over discharged. Available as 10A or 20A
Enerdrive Solar Charge Controller benefits include:
- Protects battery from overcharge and discharge
- Only for 12 Volt solar panels and batteries
- Handles up to 20 Amps of Array Current
- Handles up to 350 Watts of solar power
- Maintenance free protection of your solar panel and batteries
- Maintains battery voltage
- Maintain 12V batteries in a fully charged state
Product Features:
- LED status indicator provides quick reference to Charger, Battery and load status
- Selectable battery type
- Temperature compensation
- High precision on voltage set point
- Wall mountable
Marine
RV's
Caravans
Off-Grid Systems
Tiny Houses
Cabins
More about Enerdrive:
Enerdrive Pty Ltd has been providing independent power systems to the Australian market since 1996. Starting as Advance Trident Limited in 2003 and predominantly servicing the marine industry, ATL saw the huge growth potential in the mobile and recreational vehicle market soon after, and in 2008 ATL Limited morphed into Enerdrive. In recent times Enerdrive has embarked on its own manufacturing program. They saw the need to control their own destiny and produce high-end products that the Australian marketplace was demanding. This program has led to Enerdrive manufacturing their own range of ePOWER AC Battery Chargers & DC2DC Battery Chargers along with Lithium battery systems.
Product Specification
B-TEC 12V 200Ah G2 Lithium Battery
Model -
| EPL-200BT-12V G2 |
Nominal Voltage | 12.8V |
Nominal Capacity | 200Ah |
Cycle Life (DOD – 80% under controlled conditions) | ≥ 2000 Cycles |
Battery Charge Temperature | 0 ̴ 45°C |
Normal Charge Voltage CV/CC* | 14.20 ̴ 14.60V |
Standby (Float) Voltage | 13.50 ̴ 13.80V |
Maximum Charge Current | 150A @ 25°C for 30mins |
Recommended Charge Current For Maximum Life, Charge in the lower amperage range | 40~100A |
Battery Discharge Temperature | -20 ̴ 60°C |
Battery Output Voltage Range | 11.00 ̴ 14.60V |
Maximum Discharge/Pulse Current | 200A @ 25˚C ±5˚C for 30 mins |
Pulse Discharge Current | 450A for 1.0s |
Discharge Cut-off Voltage | ≤11.20V |
Circuit Protection | The battery is supplied with a LiFePO4 Battery Management System BMS that can monitor and optimize each single prismatic cell during charge & discharge,to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery. |
Over-charge Protection Per Cell | 3.90V ± 0.03V |
Over-charge Release Per Cell | 3.60V ± 0.05V |
Over-charge Release Method | Discharge below release voltage |
Over-discharge Protection Per Cell | 2.80V ± 0.05V |
Over-discharge Release Per Cell | 3.20V ± 0.05V |
Over-discharge Release Method | Apply Charge/Voltage ≥12.8V |
Battery Manual Reset Button | Yes |
Discharge Over Current | 220A for 30s – 450A for 1s |
Protection Reset Time | Approx 10s Auto Release |
Over Current Release Method | Disconnect Load |
Battery Discharge Over Temperature | Protection to 65°C ± 5°C Release at 50°C ± 5°C |
Battery Charge Over Temperature | Protection to 55°C ± 5°C Release at 45°C ± 5°C |
Short Circuit Protection | Auto release after 5s |
Length | 505mm |
Width | 172.5mm |
Height | 265mm |
Weight | Approx 25.0 Kg |
Case Construction | Hi Impact ABS Plastic |
Temperature & Humidity Range | ≤ 30 days -20°C ̴ 60°C, 5 ̴ 75% RH ≥ 90 days -10°C ̴ 45°C, 5 ̴ 75% RH |
Self-discharge Rate | ≤ 3% Per Month |
ePOWER 12V 40A Battery Charger
Model - | EN31240
|
Output Current (Maximum) | 40A |
Charge | 14.2 – 15.5 V |
Float | 13.4 – 13.8 V |
– Equalize | 16.0 V |
Charging Control | Four stages (Bulk/Absorption/Float/Maintenance) |
| Two stages (Bulk/Absorption) |
| Constant Power Supply (Program setting) |
| Priority Battery Bank Charging |
DC Output Bank | Three (1 fully independent, 2 common with diode isolation) |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Standby Current | < 2 mA |
AC Input Voltage (Nominal) | 90 to 265 VAC |
AC Input Operating Range |
207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max)
|
AC Input Frequency Range | 47 – 63 Hz |
Power Consumption |
700W (Full Load)
|
Power Factor Correction | Yes |
Charger Efficiency | > 82% |
Reverse Polarity | Yes, (with user replaceable fuse/s) |
Over Charge | Yes, unit shutdown |
Over Temperature | Yes, unit de-rated and shutdown |
Output Short Circuit | Yes, (with user replaceable fuse/s) |
Cooling | Forced air ventilation (thermo controlled fan) |
Temperature Setting | Hot, Normal, Cold (no sensor connected) |
Battery Temp Sensor Port | RJ12 (standard battery temp. sensor supplied) |
LCD Display (with back light) | Charging status, Battery Voltage, Output Current & Fault Codes. |
AC Input Connection | IEC with Supplied 1.2M Power Lead |
DC Output Connection | Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread |
DC Output Ground | Single Heavy Duty Common Ground Stud |
Storage Range | -40° to 70° C |
Operating Range | -20° to 60° C |
Humidity | 5-95%, relative humidity non-condensing |
Ingress Protection | IP32 (Basic drip proof in vertical orientation) |
| Base Unit Weight and Dimensions |
Weight: (kg) |
2.6
|
Dimension: (mm) L x W x H |
295 x 206 x 86
|
Optional Accessories | Remote Digital Display / Enerdrive Part Number EN3REM |
Regulatory Compliance | Complies with AS/NZS 60335.2.29 Including Australian deviations. |
12V 40A DC2DC+ Battery Charger
Model - | EN3DC40+ |
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A ~ 50A |
Output Power | 775W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (Flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when not in use | < 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
INPUT Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤ 23V input, 500W (600W allowable) ≥37.5V-45V input, 750W (800W allowable) |
INPUT Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32VDC |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |
Shipping Weight | 2.17 kg |
ePRO Plus Battery Monitor
Model - | ePRO Plus (Part No: EN55050) |
Supply voltage range | 7..70Vdc |
Supply current (@ 12V/ 24V/48V) | 10mA / 6mA / 5mA |
Input voltage range main battery (+B1) | 7..70Vdc1) |
Input voltage range second & third battery (+B2, +B3) | 1..70Vdc |
Input current range | -600..+600A2) |
Battery capacity range | 10..10000Ah |
Operating temperature range | -20..+50°C |
Storage temperature range | -30..+70°C |
Voltage (0..70V) | ± 0.01V |
Current (0..10A) | ± 0.01A |
Current (10..100A) | ± 0.1A |
Current (100..600A) | ± 1A |
State of Charge (0..100%) | ± 1% |
Time remaining (0..24hrs) | ± 1min |
Time remaining (24..240hrs) | ± 1hr |
Amphours (0..10000Ah) | ± 0.01Ah..10Ah (variable) |
Power (0..42kW) | ± 0.01W..1kW (variable) |
Temperature (-20°C..+50°C) | ± 0.5°C |
Voltage measurement accuracy | ± 0.3% |
Current measurement accuracy | ± 0.4% |
Footprint | 100 x 100mm |
Base height | 24.0mm |
Total height | 64.5mm |
Weight | 290grams |
Front panel | Ø 64.0mm |
Body diameter | Ø 51.5mm |
Total depth | 36.0mm |
Weight | 70grams |
Protection class | IP20 (CDU front panel only IP65) |
Standards | CE certified (EMC Directive 2014/30/EU) including EN50498 Automotive EMC |