ADVENTURER SYSTEM 40AC 40DC 2000X INC SIMARINE SCQ50

ADVENTURER SYSTEM 40AC 40DC 2000X INC SIMARINE SCQ50

THIS SYSTEM IS DESIGNED FOR THE END USER REQUIRING MAXIMUM POWER REQUIREMENTS ALONG WITH AC CHARGING ABILITY AND 230V INVERTER POWER • INCLUDES EN1120X PURE SINE WAVE INVERTER, EN31240 AC CHARGER, EN3DC40+ DC-DC CHARGER, SIMARINE BATTERY MONITOR & SIMARINE SCQ50 QUAD SHUNT


Brand: Enerdrive

Reference No. K-ADVENTURER-03

0

5,499.00Incl

4,999.09Excl
5499.0AUD
Add to Cart

New from Enerdrive; The Explorer, The Traveller & The Adventurer:


With Enerdrive breaking into the 4WD canopy market in recent years, we have been consistently asked by manufactures and end users to come up with a compact power solution to operate all of the electrical equipment that is ending up in the back of these canopies. From a simple system to operate a fridge and a couple of lights to a full on power station, these are the type of systems we have been asked for.

After many brainstorming sessions and 3D modelling designs, Enerdrive have produced 3 models to cover just about any customer request for power in their canopies. Introducing Enerdrives new canopy range, “The Explorer” “The Traveller” & “The Adventurer”. Let’s introduce these units from the baby of the family up to the big brother.


The Adventurer:

This system is designed for the end user requiring maximum power requirements along with AC charging ability and 230v Inverter power.  In addition to the Explorer & Traveller, The Adventurer consists of the following extra items;

- Enerdrive ePOWER 2000W AC Transfer Inverter

- Enerdrive ePOWER 40A AC charger

- Enerdrive ePOWER DC2DC40+ Vehicle/Solar Charger

- 1x Simarine Pico battery monitor plus Simarine SCQ50 quad shunt

- 4x Pre-wired Circuit Breakers for main power equipment

- 4x Contura switches for Lights & Auxiliary loads 

- Your choice of Twin USB 2.4A Hi Amp sockets to charge your mobile devices or mix it up with a 12v Output Socket

- Battery Reset button for kick starting your flat battery from the DC2DC Charger

- Simarine LCD Battery WIFI Monitoring System with option to incorporate individual load/charge information (Optional Water/Fuel Tank module also available)

- 4x additional Circuits Breakers for Air/Water Pumps and more

- Main System & Inverter Hi-Amp Circuit Breakers

- Option to replace the Simarine with the ePRO Plus Battery Monitor.


More information for products included:

EN3DC40+

SIMARINE MONITOR

SIMARINE SCQ50 QUAD SHUNT

EN31240

EN2000X


All systems are pre-wired by Enerdrive where possible so the only cabling required at installation time is load outputs, battery connection, & vehicle/solar/tank inputs. All systems are built into a unique compact box arrangement and designed to mount on either the front or rear bulkheads of the vehicles canopy. The systems are available in either passenger side or drivers side installation. Any brand of battery is suitable from Wet Sealed, AGM, Gel and Lithium.

If you are interested in having custom engraving for switch/circuit breakers to your specific requirements, this option is available at an additional cost. Enerdrive are proud to bring to market this innovative design that can be installed by the canopy manufacturer or end user in a neat one piece installation. 





 

Simarine SCQ50-

Specifications

Operating

Voltage Range

6-35 V

Temperature Range

-20 to +70°C

Power Consumption at 12V

Operating

3,5 mA

Current Measuring Channels

4

Current Measuring Range

Per Channel

0,01 – 50A

Accuracy

±0,6%

Resolution

0,01A

Sampling Rate

100ms

Maximal Current

Continuous

50A

Peak Current (<1 min)

70A

Peak Current (<5 sec)

100A

Voltage Drop at 25 A

35 mV

Maximal Voltage on Connections

35 V


Simarine Pico- 

Operating

Voltage Range

6 – 35 V

Temperature Range

-10 – +70 °C (+10 – +160 °F)

Power Consumption at 12V

Operating, Wi-Fi on, 100% illumination

90 mA

Operating, Wi-Fi on, 70% illumination

35 mA

Operating, Wi-Fi on, 0% illumination

18 mA

Power off, logger still active

5 mA

Resolution

Current

± 0.01 A

Voltage

± 0.01 V

Amp hours

± 0.1 Ah

State of charge (0 - 100%)

± 0.1 %

Temperature

± 0.1 °C/°F

Barometer

Operating range

950 – 1080 hPa

WiFi

Radio frequency bands

2.4 GHz

Dimensions (without connector)

Standalone

98 x 84 x 10 mm

3.85 x 3.30 x 0.39 in

Panel

108.5 x 94 x 10 mm

4.27 x 3.70 x 0.39 in

Connectivity

Up to

Batteries

6

Shunts

24

Temperature sensors

10

Tank level sensors

14

Inclinometer sensors

2

Smart phone application

1

Logger capacity

up to 3 months


EN3DC40+

Model

EN3DC40+

Ouput Rating

Output Voltage

12V Nominal (8.0V min)

Output Current (Maximum)

40A – 50A

Output power

775W

Charger DC Output (CH1):

Selectable Battery Type

Gel, AGM, Flooded, Lithium, Program

Charger Voltage Range

13.8V – 15.5V

Float Voltage Range

13.0V – 13.8V

Charger Current (User Selectable)

5/10/15/20/25/30/35/40/45/50A (default 40A)

Equalize Voltage (flooded Battery)

15.5V

Equalize Charging Current

10% of Bulk Current Setting

Charging Control

2 stage / 3 stage selectable (Default 3 stage)

DC Output Bank

Single

Current draw from CH1 when in use

= < 50mA

Battery Temperature Setting

Low/ Normal/ High (Battery Temperature Sensor Standard)

Efficiency

95%

Input Rating (CH2 – MPPT Solar)

Input Voltage

14.5 – 45VOC

Maximum Input

≤23 input, 500W (600W allowable) ≥37.5-45V input, 750W (800W allowable)

Input Rating (CH3 – Start/Alternator)

Input Voltage

10.5 – 16VDC / 21 – 32DC

Dimensions

Height x Width x Depth

242mm x 172mm x 74mm

Unit Weight

1.85 Kg

Shipping Weight

2.17 Kg


EN31240-

Model

EN31220

EN31240

EN31260

EN32430

CHARGER OUTPUT

Output Current (Maximum)

20A

40A

60A

30A

OUTPUT VOLTAGE RANGE

Charge

14.2 – 15.5 V

28.4 – 31.0V

Float

13.4 – 13.8 V

26.8 – 27.6V

– Equalize

16.0 V

32.0V

Charging Control

Four stages (Bulk/Absorption/Float/Maintenance)

Two stages (Bulk/Absorption)

Constant Power Supply (Program setting)

Priority Battery Bank Charging

DC Output Bank

Three (1 fully independent, 2 common with diode isolation)

Selectable Battery Type

Gel, AGM, Flooded, Lithium, Program

Standby Current

< 2 mA

CHARGER INPUT

AC Input Voltage (Nominal)

90 to 265 VAC

AC Input Operating Range

207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max)

207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max)

207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)

207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)

AC Input Frequency Range

47 – 63 Hz

Power Consumption

350W (Full Load)

700W (Full Load)

1050W (Full Load)

1050W (Full Load)

Power Factor Correction

Yes

Charger Efficiency

> 82%

PROTECTION AND FEATURES

Reverse Polarity

Yes, (with user replaceable fuse/s)

Over Charge

Yes, unit shutdown

Over Temperature

Yes, unit de-rated and shutdown

Output Short Circuit

Yes, (with user replaceable fuse/s)

Cooling

Forced air ventilation (thermo controlled fan)

Temperature Setting

Hot, Normal, Cold (no sensor connected)

Battery Temp Sensor Port

RJ12 (standard battery temp. sensor supplied)

DISPLAY

LCD Display (with back light)

Charging status, Battery Voltage, Output Current & Fault Codes.

AC INPUT AND DC OUTPUT CONNECTION

AC Input Connection

IEC with Supplied 1.2M Power Lead

DC Output Connection

Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread

DC Output Ground

Single Heavy Duty Common Ground Stud

ENVIRONMENTAL AND OPERATING TEMPERATURE

Storage Range

-40° to 70° C

Operating Range

-20° to 60° C

Humidity

5-95%, relative humidity non-condensing

Ingress Protection

IP32 (Basic drip proof in vertical orientation)

Base Unit Weight and Dimensions

Weight: (kg)

2.4

2.6

4.0

4.0

Dimension: (mm) L x W x H

295 x 206 x 86

295 x 206 x 86

356 x 206 x 99

356 x 206 x 99

Optional Accessories

Remote Digital Display / Enerdrive Part Number EN3REM

Regulatory Compliance

Complies with AS/NZS 60335.2.29 Including Australian deviations.


EN1120X-

Model – Description

EN1120X

EN1120X-24v

EN1126X

AC Output Power

2000W

2000W

2600W

AC Output Current

8.7A

8.7A

11.3A

AC Output Voltage

230 Vac / 50 Hz

AC Output Waveform

Sinewave (<3% THD)

Nominal DC Input Voltage

12.5 VDC

No Load battery draw

< 1.5 ADC

DC Input Voltage operating range

10.5 – 15.5 VDC

21.0 – 31.0 VDC

10.5 – 15.5 VDC

Under Voltage Alarm

11.0 / 12.1 VDC

22.0 / 24.2 VDC

11.0 / 12.1 VDC

Under Voltage Alarm Recovery

11.3 / 12.3 VDC

22.6 / 24.6 VDC

11.3 / 12.3 VDC

Under Voltage Shutdown

10.5 / 11.8 VDC

21.0 / 23.6 VDC

10.5 / 11.8 VDC

Under Voltage Shutdown Recovery

12.0 / 12.6 VDC

24.0 / 25.2 VDC

12.0 / 12.6 VDC

Over Voltage Shutdown

15.5 VDC

31.0 VDC

15.5 VDC

USB Port

5V, 750 mA

AC Transfer Switch

Transfer Time

< 30 ms

Transfer Relay Rating

16A (resistive load)

AC Input socket IEC-C20

16A max

AC Output socket IEC-C19

16A max

AC Output Front GPO

10A max

Safety and Environmental

Conformance

All required Australian Standards , CE LVD: EN/IEC 62040-1, IEC61558-2-16

EMI / EMC

CE EMC: EN/IEC 62040-2 category C1

Agency Markings

RCM , CE

Operating Temperature

0°C to 40°C

Storage Temperature

-20°C to 60°C

Relative Humidity

5-90% non-condensing

Operating Altitude

Up to 3000 meters above sea level

Weights and Dimensions

Weight

5.9 kg

5.9 kg

7.0 kg

Dimensions (W x L x H)

435x230x115 mm

560x230x115 mm

Warranty

2 Years

Simarine SCQ shunt manual-

Simarine system Overview-


Simarine SCQ wiring Diagrams-

Simarine Pico manual-

Enerdrive EN3DC40+ spec sheet- 


Enerdrive EN3DC40+ manual-

Enerdrive EN31240 spec sheet-


Enerdrive EN31240 manual-

Enerdrive EN1120X spec sheet-


Enerdrive EN1120X manual-