TRAVELLER SYSTEM 40AC 40DC INC EPRO+
THIS SYSTEM IS DESIGNED FOR THE END USER REQUIRING A HIGHER LEVEL OF POWER REQUIREMENTS ALONG WITH AC CHARGING ABILITY • INCLUDES EN31240 AC CHARGER, EN3DC40+ DC-DC CHARGER & EPRO+ BATTERY MONITOR
Brand: Enerdrive
Reference No. K-TRAVELLER-01
New from Enerdrive; The Explorer, The Traveller & The Adventurer:
With Enerdrive breaking into the 4WD canopy market in recent years, we have been consistently asked by manufactures and end users to come up with a compact power solution to operate all of the electrical equipment that is ending up in the back of these canopies. From a simple system to operate a fridge and a couple of lights to a full on power station, these are the type of systems we have been asked for.
After many brainstorming sessions and 3D modelling designs, Enerdrive have produced 3 models to cover just about any customer request for power in their canopies. Introducing Enerdrives new canopy range, “The Explorer” “The Traveller” & “The Adventurer”. Let’s introduce these units from the baby of the family up to the big brother.
The Traveller:
This system is designed for the end user requiring a higher level of power requirements along with AC charging ability. In addition to the Explorer, The Traveller consists of the following extra items;
- Enerdrive ePOWER 40A AC charger
- Enerdrive ePOWER DC2DC40+ Vehicle/Solar Charger
- 1x ePRO Plus Battery Monitor
- 4x Pre-wired Circuit Breakers for main power equipment
- 4x Contura switches for Lights & Auxiliary loads
- Pre-wired Battery & Fridge Anderson Plugs (Explorer & Traveller only)
- Your choice of Twin USB 2.4A Hi Amp sockets to charge your mobile devices or mix it up with a 12v Output Socket
- Battery Reset button for kick starting your flat battery from the DC2DC Charger
- Option to replace the ePRO Plus Battery Monitor with the Simarine.
More information for products included:
All systems are pre-wired by Enerdrive where possible so the only cabling required at installation time is load outputs, battery connection, & vehicle/solar/tank inputs. All systems are built into a unique compact box arrangement and designed to mount on either the front or rear bulkheads of the vehicles canopy. The systems are available in either passenger side or drivers side installation. Any brand of battery is suitable from Wet Sealed, AGM, Gel and Lithium.
If you are interested in having custom engraving for switch/circuit breakers to your specific requirements, this option is available at an additional cost. Enerdrive are proud to bring to market this innovative design that can be installed by the canopy manufacturer or end user in a neat one piece installation.
Epro+
Parameter | ePRO Plus (Part No: EN55050) | |
Supply voltage range | 7..70Vdc | |
Supply current (@ 12V/ 24V/48V) | 10mA / 6mA / 5mA | |
Input voltage range main battery (+B1) | 7..70Vdc | |
Input voltage range second & third battery (+B2, +B3) | 1..70Vdc | |
Input current range | -600..+600A | |
Battery capacity range | 10..10000Ah | |
Operating temperature range | -20..+50°C | |
Storage temperature range | -30..+70°C | |
Readout resolution | Voltage (0..70V) | ± 0.01V |
Current (0..10A) | ± 0.01A | |
Current (10..100A) | ± 0.1A | |
Current (100..600A) | ± 1A | |
State of Charge (0..100%) | ± 1% | |
Time remaining (0..24hrs) | ± 1min | |
Time remaining (24..240hrs) | ± 1hr | |
Amphours (0..10000Ah) | ± 0.01Ah..10Ah (variable) | |
Power (0..42kW) | ± 0.01W..1kW (variable) | |
Temperature (-20°C..+50°C) | ± 0.5°C | |
Voltage measurement accuracy | ± 0.3% | |
Current measurement accuracy | ± 0.4% | |
Shunt dimensions: | Footprint | 100 x 100mm |
Base height | 24.0mm | |
Total height | 64.5mm | |
Weight | 290grams | |
Display dimensions: | Front panel | Ø 64.0mm |
Body diameter | Ø 51.5mm | |
Total depth | 36.0mm | |
Weight | 70grams | |
Protection class | IP20 (CDU front panel only IP65) | |
Standards | CE certified (EMC Directive 2014/30/EU) including EN50498 Automotive EMC |
EN3DC40+
Model | EN3DC40+ |
Ouput Rating | |
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A – 50A |
Output power | 775W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when in use | = < 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
Input Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤23 input, 500W (600W allowable) ≥37.5-45V input, 750W (800W allowable) |
Input Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32DC |
Dimensions | |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |
Shipping Weight | 2.17 Kg |
EN31240-
Model | EN31220 | EN31240 | EN31260 | EN32430 |
CHARGER OUTPUT | ||||
Output Current (Maximum) | 20A | 40A | 60A | 30A |
OUTPUT VOLTAGE RANGE | ||||
Charge | 14.2 – 15.5 V | 28.4 – 31.0V | ||
Float | 13.4 – 13.8 V | 26.8 – 27.6V | ||
– Equalize | 16.0 V | 32.0V | ||
Charging Control | Four stages (Bulk/Absorption/Float/Maintenance) | |||
Two stages (Bulk/Absorption) | ||||
Constant Power Supply (Program setting) | ||||
Priority Battery Bank Charging | ||||
DC Output Bank | Three (1 fully independent, 2 common with diode isolation) | |||
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program | |||
Standby Current | < 2 mA | |||
CHARGER INPUT | ||||
AC Input Voltage (Nominal) | 90 to 265 VAC | |||
AC Input Operating Range | 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) | 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
AC Input Frequency Range | 47 – 63 Hz | |||
Power Consumption | 350W (Full Load) | 700W (Full Load) | 1050W (Full Load) | 1050W (Full Load) |
Power Factor Correction | Yes | |||
Charger Efficiency | > 82% | |||
PROTECTION AND FEATURES | ||||
Reverse Polarity | Yes, (with user replaceable fuse/s) | |||
Over Charge | Yes, unit shutdown | |||
Over Temperature | Yes, unit de-rated and shutdown | |||
Output Short Circuit | Yes, (with user replaceable fuse/s) | |||
Cooling | Forced air ventilation (thermo controlled fan) | |||
Temperature Setting | Hot, Normal, Cold (no sensor connected) | |||
Battery Temp Sensor Port | RJ12 (standard battery temp. sensor supplied) | |||
DISPLAY | ||||
LCD Display (with back light) | Charging status, Battery Voltage, Output Current & Fault Codes. | |||
AC INPUT AND DC OUTPUT CONNECTION | ||||
AC Input Connection | IEC with Supplied 1.2M Power Lead | |||
DC Output Connection | Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread | |||
DC Output Ground | Single Heavy Duty Common Ground Stud | |||
ENVIRONMENTAL AND OPERATING TEMPERATURE | ||||
Storage Range | -40° to 70° C | |||
Operating Range | -20° to 60° C | |||
Humidity | 5-95%, relative humidity non-condensing | |||
Ingress Protection | IP32 (Basic drip proof in vertical orientation) | |||
Base Unit Weight and Dimensions | ||||
Weight: (kg) | 2.4 | 2.6 | 4.0 | 4.0 |
Dimension: (mm) L x W x H | 295 x 206 x 86 | 295 x 206 x 86 | 356 x 206 x 99 | 356 x 206 x 99 |
Optional Accessories | Remote Digital Display / Enerdrive Part Number EN3REM | |||
Regulatory Compliance | Complies with AS/NZS 60335.2.29 Including Australian deviations. |