PHOENIX INVERTER 12/375

VICTRON PURE SINEWAVE INVERTER 12V 375VA • VE DIRECT 230V AU/NZ


Brand: Victron

Reference No. PIN123750300

0

139.00 Incl

126.36 Excl
Add to Cart

VE.Direct communication port


The VE.Direct port can be connected to:


A computer (VE.Direct to USB interface cable needed)


Apple and Android smartphones, tablets, MacBook’s and other devices (VE.Direct Bluetooth Smart dongle needed)


Fully configurable:


Low battery voltage alarm trip and reset levels


Low battery voltage cut-off and restart levels


Dynamic cut-off: load dependent cut-off level


Output voltage 210 - 245V


Frequency 50 Hz or 60 Hz


ECO mode on/off and ECO mode sense level


Monitoring:


In- and output voltage, % load and alarms


Proven reliability


The full bridge plus toroidal transformer topology has proven its reliability over many years.  The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.


High start-up power


Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.


ECO mode


When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.


Remote on/off


A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.


LED diagnosis


Please see manual for a description.


To transfer the load to another AC source: the automatic transfer switch


For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.

                                             12Volt

PhoenixInverter                              24Volt

                                    48Volt

12/250

24/250

48/250

12/375

24/375

48/375

12/500

24/500

48/500

12/800

24/800

48/800

12/1200

24/1200

48/1200

Cont. power at 25°C (1)

250VA

375VA

500VA

800VA

1200VA

Cont. power at 25°C / 40°C

200/175W

300/260W

400/350W

650/560W

1000/850W

Peak power

400W

700W

900W

1500W

2200W

Output AC voltage / frequency (adjustable)

230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%

Input voltage range

9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V

DC low shut down (adjustable)

9,3 / 18,6 / 37,2V

Dynamic

(load dependent)

DC low shut down

(fully configurable)

Dynamic cut-off, see

https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff

DC low restart and alarm (adjustable)

10,9 / 21,8 / 43,6V

Battery charged detect (adjustable)

14,0 / 28,0 / 56,0V

Max. efficiency

87/88/88%

89/89/90%

90/90/91%

90/90/91%

91/91/92%

Zero-load power

4,2/5,2/7,9W

5,6/6,1/8,5W

6/6,5/9W

6,5/7/9,5W

7/8/10W

Default zero-load power in ECO mode

(default retry interval: 2,5 s, adjustable)

0,8/1,3/2,5W

0,9/1,4/2,6W

1/1,5/3,0

1/1,5/3,0

1/1,5/3,0

ECO mode stop and start power setting

Adjustable

Protection (2)

a - f

Operating temperature range

-40 to +65°C (fanassistedcooling)Derate 1,25% per °C above40°C

Humidity (non-condensing)

max 95%

ENCLOSURE

Material & Colour

Steel chassis and plastic cover (blue Ral 5012)

Battery-connection

Screw terminals

Maximum cable cross-section

10 mm²/AWG8

10 mm²/AWG8

10 mm²/AWG8

25/10/10mm²/

AWG 4/8/8

35/25/25 mm2/AWG 2/4/4

 

Standard AC outlets

230V: Schuko (CEE 7/4), IEC-320 (male plug included)

UK (BS 1363), AU/NZ (AS/NZS 3112)

120V: Nema 5-15R

Protection category

IP 21

Weight

2,4kg/5,3lbs

3,0kg/6,6lbs

3,9kg/8.5lbs

5,5kg/12lbs

7,4kg/16,3lbs

Dimensions (hxwxd, mm)

(hxwxd, inch)

86x165x260

3.4x6.5x10.2

86x165x260

3.4x6.5x10.2

86x172x275

3,4x6,8x10,8

105x216x305

4.1x8.5x12.1

(12V model: 105x230x325)

117x232x327

4.6x9.1x12.9

(12V model: 117x232x362)

ACCESSORIES

Remote on-off

Yes

Automatic transfer switch

Filax

STANDARDS

Safety

EN-IEC 60335-1 / EN-IEC 62109-1

EMC

EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3

Automotive Directive

ECE R10-4

1)  Nonlinear load, crest factor3:1

2)  Protectionkey:

a)  output shortcircuit

b)  overload

c)  batteryvoltagetoohigh

d)  battery voltage toolow

e)  temperature toohigh

f)  DC ripple toohigh

Spec Sheet-


Manual-