30kW Three Phase Hybrid Inverter | |
Output Data | |
Rated AC Power Output | 30,000VA |
Maximum AC Power Output | 30,000VA |
AC Output Voltage - Line to Line / Line to Neutral (Nominal) | 380/220V; 400/230V AC |
AC Output Voltage Range - Line to Neutral Range | 176-253V: 184-264.5V AC |
AC Output Line Connections
| 3W + PE, 4W + PE
|
Grid Supported - Three Phase
| WYE: TN-C, TN-S, TN-C-S, IT; Delta: IT
|
AC Frequency (Nominal) | 50 ± 5% |
Rated Continuous Output Current (Per Phase) | 43.5A |
Maximum Continuous Overcurrent Protection
| 43.5A
|
Residual Current Detector / Residual Current Step Detector
| 100 / 30mA
|
Inrush Current AC (Peak / Duration)
| 3.6Aac rms / 20ms
|
Maximum Residual Current Injection
| 100mA
|
Maximum Output Fault Current
| 66Aac
|
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds | Yes |
Total Harmonic Distortion
| < 3%
|
Protective Class
| Class I
|
Overvoltage Category
| III
|
Anti-Islanding Method
| Slip Mode Frequency Shift
|
Power Factor Range
| +/-0.8 to 1
|
Input Data | |
Maximum DC Power | 52,500W |
Transformer-less, Ungrounded | Yes |
Operating Voltage Range DC+ to DC-
| 680-1000V DC
|
Minimum Input Voltage DC to Gnd
| 340V DC
|
Maximum Input Voltage DC to Gnd
| 415V DC
|
Maximum Input Voltage DC+ to DC- | 1000V DC |
Maximum Operating Input Current | 43.5A DC |
Short Circuit Current From the PV Array
| 48.25A DC
|
Maximum Feedback Current
| 0A DC
|
Overvoltage Category
| II
|
Reverse-Polarity Protection | Yes |
Ground-Fault Isolation Detection | 167kΩ Sensitivity |
Protective Class
| Class I
|
Overvoltage Category
| II
|
Maximum Inverter Efficiency | 98.3% |
Nighttime Power Consumption | < 4W |
Additional Features | |
Supported Communication Interfaces | 2x RS485, Ethernet, Wi-Fi |
Smart Energy Management | Export Limitation |
Inverter Commissioning | Within the SetApp mobile application using built-in Wi-Fi Access-Point for local connection |
Arc Fault Protection
| Integrated, User Configurable
|
RS485 Surge Protection
| Supplied with the inverter
|
DC / AC Surge Protection
| Type II, field replaceable, optional
|
Maximum Altitude
| 2000m
|
Inverter Topology
| Non-Isolated Photovoltaic Inverter
|
DC Safety Unit
|
|
DC Disconnect
| Provided
|
Installation Specifications | |
AC Output Conduit Size / Wire cross-section | 20mm minimum / 4-16 mm² |
DC Input Conduit Size / Wire cross-section | 20mm minimum / 6-35 mm²
|
Dimensions | 808 x 317 x 300mm |
Weight | 35kg |
Noise | < 62 dBA |
Cooling | Fan (user replaceable) |
Operating Temperature Range | -40ºC to +60ºC |
Protection Rating | IP65 — Outdoor and Indoor |
Mounting | Bracket Provided |
Standard Compliance | |
Safety | IEC62109, AS/NZS3100 |
Grid Connection Standards | AS/NZS4777:2020
|
Emissions | IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12
|
RoHS | Yes |