Victron MultiPlus 500VA-1600VA:
 
The new style MultiPlus is set to replace the earlier MultiPlus Compact range. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single compact enclosure.

In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Monitor and control your MultiPlus and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your MultiPlus to setting a Geofence for hire vehicles and more...
 

Features:

Proven reliability- The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.


PowerControl - Dealing with limited generator, shore side or grid power (800VA/1200VA)- With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever  is extra for charging, thus preventing the generator or shore supply from being overloaded.


PowerAssist - Boosting the capacity of shore or generator power (800VA/1200VA)- Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.


High start-up power- Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.


Search Mode- When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.


Programmable relay- By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low). 


Remote on / off / charger on- Three pole connector

 

12Volt

MultiPlus       24Volt

48Volt

C 12/800/35 C 24/ 800/16

C 12/1200/50 C 24/1200/25

C 12/1600/70 C 24/1600/40

C 12/2000/80 C 24/2000/50

12/3000/120

24/3000/70

48/3000/35

 

24/5000/120

48/5000/70

PowerControl

Yes

Yes

Yes

Yes

Yes

Yes

PowerAssist

Yes

Yes

Yes

Yes

Yes

Yes

Transfer switch (A)

16

16

16

30

16 or 50

100

INVERTER

Input voltage range (V DC)

9,5 –17V   19 –33 V       38 – 66V

Output

Output voltage: 230 VAC±2%    Frequency: 50 Hz ± 0,1%(1)

Cont. output power at 25°C (VA) (3)

800

1200

1600

2000

3000

5000

Cont. output power at 25°C (W)

700

1000

1300

1600

2400

4000

Cont. output power at 40°C (W)

650

900

1200

1400

2200

3700

Cont. output power at 65°C (W)

400

600

800

1000

1700

3000

Peak power (W)

1600

2400

3000

4000

6000

10.000

Maximum efficiency (%)

92 / 94

93 / 94

93 / 94

93 / 94

93 / 94 / 95

94 / 95

Zero load power (W)

8 / 10

8 / 10

8 / 10

9 / 11

20 / 20 / 25

30 / 35

Zero load power in AES mode (W)

5 / 8

5 / 8

5 / 8

7 / 9

15 / 15 / 20

25 / 30

Zero load power in Search mode (W)

2 / 3

2 / 3

2 / 3

3 / 4

8 / 10 / 12

10 / 15

CHARGER

AC Input

Input voltage range:187-265VAC    Input frequency: 45 –65 Hz        Power factor:1

Charge voltage 'absorption' (V DC)

14,4 / 28,8 / 57,6

Charge voltage 'float' (V DC)

13,8 / 27,6 / 55,2

Storage mode (V DC)

13,2 / 26,4 / 52,8

Charge current house battery (A) (4)

35 / 16

50 / 25

70 / 40

80 / 50

120 / 70 / 35

120 / 70

Charge current starter battery (A)

4 (12 V and 24 V models only)

Battery temperature sensor

yes

GENERAL

Auxiliary output (5)

n. a.

n. a.

n. a.

n. a.

Yes (16A)

Yes (50A)

Programmable relay (6)

Yes

Protection (2)

a - g

VE.Bus communication port

For parallel and three phase operation, remote monitoring and system integration

General purpose com. port

n. a.

n. a.

n. a.

n. a.

Yes

Yes

Remote on-off

Yes

Common Characteristics

Operating temp. range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing): max 95%

ENCLOSURE

Common Characteristics Battery-connection

230 V AC-connection

Material & Colour: aluminium (blueRAL5012)   Protection category: IP21

battery cables of 1.5 meter

G-ST18i connector

M8 bolts

Spring-clamp

Four M8 bolts (2 plus and 2 minus connections)

Screw terminals 13

mm2 (6 AWG)

M6 bolts

Weight (kg)

10

10

10

12

18

30

Dimensions (hxwxd in mm)

375x214x110

520x255x125

362x258x218

444x328x240

STANDARDS

Safety

EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1

Emission, Immunity

EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Road vehicles

12V and 24V models: ECE R10-4

Anti-islanding

See our website

1)  Canbeadjustedto60HZ;120V60Hzonrequest

2)  Protectionkey:

a)  output short circuit

b)  overload

c)  batteryvoltagetoohigh

d)  batteryvoltagetoolow

e)  temperature toohigh

f)230 VAC on inverteroutput

g)  input voltage ripple toohigh

 

3)  Non-linear load, crest factor3:1

4)  At 25˚Cambient

5)  SwitchesoffwhennoexternalACsourceavailable

6)  Programmablerelaythatcana.o.besetforgeneralalarm, DCundervoltageorgensetstart/stopfunction

AC rating: 230 V/4A

DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC

 

 

 Spec Sheet-


Product Dimensions-


Manual-


Interfacing with VE Bus Products - MK2 Protocol